Високопродуктивні АЦП комбінованого врівноваження
Author
Багацький, В. О.
Обертюх, М. Р.
Захарченко, С. М.
Date
2022Metadata
Show full item recordCollections
- Наукові роботи каф. ОТ [746]
Abstract
Today analog-to-digital converters are used in computing and control systems which have greatly expanded in the era of the
digital revolution. Increasing the accuracy, speed, energy efficiency, and reliability of analog-to-digital converters is extremely important.
One of the most classic types of analog-to-digital converters is the sequential approximation and tracking type ADCs. The conversion time of
the tracking type ADC is variable and is determined by the difference between the two readings of the input voltage. Therefore, combining
the tracking approach and the method of successive approximation in the case of sharp jumps in the input signal allows you to significantly
improve the conversion characteristic. Also the use of redundant counting systems for the weights of the ADC digits has significant
advantages, which makes it possible to significantly increase the linearity of the conversion characteristic. The methods of construction of
ADCs working on the principle of successive approximation and analog-digital converters whose operation algorithm is tracking are
considered. A method of constructing a combined type ADC is proposed, which combines a follow-up conversion algorithm and a sequential
approximation algorithm, which allows to improve the characteristics of ADC conversion. The expediency of using a combined type of
redundant positional counting systems in ADCs has been proven. The analyzed property of redundant positional counting systems, which is
inherent in them when the real weights of the digits deviate from their theoretical values, ensures the absence of "gaps" in the conversion
characteristic, as well as the ability to perform the procedure of self-calibration of the weights of the ADC digits, thereby significantly
improving the linearity of the conversion characteristic. It is indicated that even with the lengthening of the bit grid for ADCs built on the
basis of redundant positional counting systems, their performance does not decrease. Доведено доцільність використання в АЦП
комбінованого типу надлишкових позиційних систем числення. Проаналізовано властивість надлишкових
позиційних систем числення (НПСЧ), що притаманна їм за умови відхилення реальних ваг розрядів від їхніх
теоретичних значень, – забезпечувати відсутність \"розривів\" у перетворювальній характеристиці, а також
здатність виконувати процедуру самокалібрування ваг розрядів АЦП, тим самим значно покращуючи лінійність
перетворювальної характеристики. Вказано, що навіть за подовження розрядної сітки для АЦП, побудованих на
базі надлишкових позиційних систем числення, не відбувається зменшення їх швидкодії.
URI:
http://ir.lib.vntu.edu.ua//handle/123456789/36900