<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Optimal Determination Method of the Transposition Steps of An Extra-High Voltage Power Transmission Line

dc.contributor.authorKhasawneh, A.en
dc.contributor.authorQawaqzeh, M.en
dc.contributor.authorKuchanskyy, V.en
dc.contributor.authorRubanenko, O.en
dc.contributor.authorMiroshnyk, O.en
dc.contributor.authorShchur, T.en
dc.contributor.authorDrechny, M.en
dc.contributor.authorРубаненко, О. О.uk
dc.titleOptimal Determination Method of the Transposition Steps of An Extra-High Voltage Power Transmission Lineen
dc.date.issued2021
dc.publisherMultidisciplinary Digital Publishing Institute
dc.identifier.citationOptimal Determination Method of the Transposition Steps of An Extra-High Voltage Power Transmission Line [Electronic resource] / A. Khasawneh, M. Qawaqzeh, O. Rubanenko [etc.] // Energies. – 2021. – Vol. 14, № 20. – Access mode: https://doi.org/10.3390/en14206791.en
dc.relation.ispartofEnergies. Vol. 14, № 20.en
dc.identifier.urihttp://ir.lib.vntu.edu.ua/handle/123456789/34199
dc.description.abstractПід час проєктування надвисоковольтних ліній електропередачі виконано дослідження впливу несиметрії, зумовленої різницею фаз параметрів, на її процеси та електричну мережу. Для компенсації цього джерела несиметрії для ліній електропередачі довжиною понад 100 км було запропоновано та реалізовано відносно простий технічний засіб — транспозицію фаз (зміну взаємного розташування фазних проводів у просторі). Проте водночас транспозиція спричиняє додаткові капітальні витрати на будівництво та знижує надійність під час експлуатації, тому під час проєктування конкретної надвисоковольтної лінії електропередачі бажано оцінити ефективність застосування цього заходу в реальній електричній мережі. Так, за певних умов навіть для лінії електропередачі завдовжки 600 км можна було виконати або неповний цикл транспозиції, або взагалі відмовитися від цього заходу.uk
dc.description.abstractDuring the design of extra-high-voltage transmission lines, studies of the influence of asymmetry due to the phase difference of the parameters on its processes and the electrical network were performed. To compensate for this source of asymmetry for transmission lines longer than 100 km, a relatively simple technical means was proposed and implemented—phase transposition (change of the mutual location of phase wires in space). However, at the same time transposition causes additional capital costs in construction and reduces reliability during operation, so when designing a specific transmission line, extra-high-voltage is desirable to evaluate the effectiveness of the use of this measure in the real electricity network. Thus, under certain conditions, even for a transmission line 600 km in length, it was possible to perform either an incomplete transposition cycle, or abandon this measure altogether.en
dc.subjectscheme transposition phase asymmetryen
dc.subjectnatural poweren
dc.subjectSTATCOMen
dc.subjectcontrolled shunt reactoren
dc.subjectFACTSen
dc.subjectсхема транспозиціїuk
dc.subjectфазова асиметріяuk
dc.subjectнатуральна потужністьuk
dc.subjectSTATCOMuk
dc.subjectкерований шунтувальний реакторuk
dc.subjectFACTSuk
dc.typeArticle
dc.language.isoenen
dc.date.accessioned2021-11-17T12:59:47Z
dc.date.available2021-11-17T12:59:47Z

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
87829.pdf
Розмір:
1,3 MB
Формат:
Adobe Portable Document Format

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
license.txt
Розмір:
129 B
Формат:
Plain Text
Опис: