<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Development and investigation of a four-channel ultrasonic flowmeter with equal signal paths

dc.contributor.authorBilynskyi, Y.en
dc.contributor.authorStetsenko, A.en
dc.contributor.authorБілинський, Й. Й.uk
dc.contributor.authorСтеценко, А. А.uk
dc.titleDevelopment and investigation of a four-channel ultrasonic flowmeter with equal signal pathsen
dc.date.issued2026
dc.publisherGlobal Science Center LPen
dc.identifier.citationBilynskyi Y., Stetsenko A. Development and investigation of a four-channel ultrasonic flowmeter with equal signal paths // Polish journal of science. 2026. № 98. Р. 73-77.en
dc.relation.ispartofPolish journal of science. № 98 : 73-77.en
dc.identifier.issn3353-2389
dc.identifier.urihttps://ir.lib.vntu.edu.ua/handle/123456789/51533
dc.description.abstractУ статті запропоновано нову модель чотириканального ультразвукового витратоміра. Вимірювальний пристрій працює, на відміну від класичного, з двома групами ультразвукових променів, при цьому вони мають однакову довжину шляху сигналу. Така конструкція дає змогу зменшити похибку вимірювання, оскільки не потребує урахування різниці довжин акустичних шляхів, як у традиційних схемах, що виникає внаслідок викривлення труби. Для підтвердження роботи витратоміра подано його математичну модель. Результати порівняно з математичною моделлю класичного чотириканального витратоміра, і вони показали вищі показники точності. У класичних схемах похибки, пов’язані з геометрією, накопичуються для кожного променя. У запропонованій конфігурації похибки мають спільну природу й частково компенсуються, тому загальна невизначеність вимірювання зменшується. Оцінено сумарну похибку вимірювання витрати, яка на 10–15 % менша порівняно з класичними витратомірами. Отримані результати також підтверджено моделюванням витратомірів у середовищі SOLIDWORKS Flow Simulation.uk
dc.description.abstractThe paper proposes a new model of a four-channel ultrasonic flowmeter. The measuring device operates, unlike the classical one, with two groups of ultrasonic beams, and at the same time they have equal signal path lengths. Such a design makes it possible to reduce the measurement error, since it does not require taking into account the difference in the lengths of acoustic paths, as in traditional schemes, which arises as a result of pipe curvature. To confirm the operation of the flowmeter, its mathematical model is presented. The results were compared with the mathematical model of a classical four-channel flowmeter and showed higher accuracy indicators. In classical schemes, errors associated with geometry accumulate for each beam. In the proposed configuration, the errors have a common nature and are partially compensated, and therefore the overall measurement uncertainty is reduced. The total flow measurement error is estimated, which is 10–15% lower compared to classical flowmeters. The obtained results are also confirmed by modeling of flowmeters in the SOLIDWORKS Flow Simulation environment.en
dc.subjectultrasonic flowmeteren
dc.subjectmeasurement erroren
dc.subjectbeam lengthen
dc.subjectinclination angleen
dc.subjectmetrological evaluationen
dc.subjectpartial derivativesen
dc.subjectультразвуковий витратомірuk
dc.subjectпохибка вимірюванняuk
dc.subjectдовжина променяuk
dc.subjectкут нахилуuk
dc.subjectметрологічне оцінюванняuk
dc.subjectчастинні похідніuk
dc.typeArticle, professional foreign edition
dc.typeArticle
dc.language.isoenen
dc.date.accessioned2026-05-15T13:03:54Z
dc.date.available2026-05-15T13:03:54Z

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
201367.pdf
Розмір:
753,96 KB
Формат:
Adobe Portable Document Format

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
license.txt
Розмір:
129 B
Формат:
Plain Text
Опис: