<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

System and algorithm for evaluation of human auditory analyzer state

dc.contributor.authorBachynskiy, M. V.en
dc.contributor.authorAzarkhov, O. Yu.en
dc.contributor.authorShtofel, D. Kh.en
dc.contributor.authorHorbatiuk, S. M.en
dc.contributor.authorŁawicki, T. Ł.en
dc.contributor.authorKalizhanova, A.en
dc.contributor.authorSmailova, S.en
dc.contributor.authorAskarova, N.en
dc.titleSystem and algorithm for evaluation of human auditory analyzer stateen
dc.title.alternativeСистема і алгоритм для оцінювання стану слухового аналізатора людиниuk
dc.date.issued2017-08-07
dc.publisherInternational Society for Optics and Photonicsen
dc.identifier.citationSystem and algorithm for evaluation of human auditory analyzer state [Electronic resource] / Mykhaylo V. Bachynskiy, Oleksandr Yu. Azarkhov, Dmytro Kh. Shtofel [et alc.] // Proc. SPIE 10445 "Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2017. — Vol. 10445, Article No 1044537. — DOI: 10.1117/12.2280738.en
dc.relation.ispartofProc. SPIE 10445 "Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2017. Vol. 10445, Article No 1044537.en
dc.identifier.doi10.1117/12.2280738
dc.identifier.issn0277-786X
dc.identifier.urihttp://ir.lib.vntu.edu.ua/handle/123456789/19935
dc.description.abstractУ роботі розглянуто питання оцінювання стану слуху людини технічними засобами. Розглянуто недоліки наявних клінічних методів і систем аудіометрії. Для підвищення об’єктивності та ефективності медичного дослідження запропоновано використати метод оцінювання стану слухового аналізатора за допомогою пульсометрії. Передбачено використання двох оптоелектронних датчиків, розташованих на сонній артерії та мочці вуха. За цим методом розроблено біотехнічну систему для оцінювання та стимуляції стану слухового аналізатора людини. Обґрунтовано її апаратне та програмне забезпечення. Випробувано різні режими моделювання в розробленій системі та досліджено вплив процедури на пацієнта.uk
dc.description.abstractThe paper discusses questions of human auditory state evaluation with technical means. It considers the disadvantages of existing clinical audiometry methods and systems. It is proposed to use method for evaluating of auditory analyzer state by means of pulsometry to get the medical study more objective and efficient. It provides for use of two optoelectronic sensors located on the carotid artery and ear lobe, Using this method the biotechnical system for evaluation and stimulation of human auditory analyzer stare wad developed. Its hardware and software were substantiated. Different modes of simulation in the designed system were tested and the influence of the procedure on a patient was studied.en
dc.subjectauditory analyzeren
dc.subjectfunctional stateen
dc.subjectbiotechnical systemen
dc.subjectalgorithmen
dc.subjectpulse characteristicen
dc.subjectsimulation modesen
dc.subjectслуховий аналізаторuk
dc.subjectфункціональний станuk
dc.subjectбіотехнічна системаuk
dc.subjectалгоритмuk
dc.subjectімпульсна характеристикаuk
dc.subjectрежими моделюванняuk
dc.typeArticle
dc.language.isoenen
dc.date.accessioned2018-03-27T10:20:48Z
dc.date.available2018-03-27T10:20:48Z

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
Bachynskiy_2017.pdf
Розмір:
331,88 KB
Формат:
Adobe Portable Document Format
Опис:

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
license.txt
Розмір:
10,07 KB
Формат:
Item-specific license agreed upon to submission
Опис: