Improving the Information Security of Modern Telecommunications Networks
| dc.contributor.author | Vasylkivsky, M. V. | en |
| dc.contributor.author | Antonyuk, H. L. | en |
| dc.contributor.author | Poludenko, O. S. | en |
| dc.contributor.author | Васильківський, М. В. | uk |
| dc.title | Improving the Information Security of Modern Telecommunications Networks | en |
| dc.date.issued | 2021 | |
| dc.publisher | Institute of Electrical and Electronics Engineers | en |
| dc.identifier.citation | Vasylkivsky M. V., Antonyuk H. L., Poludenko O. S. Improving the Information Security of Modern Telecommunications Networks // 2021 IEEE 3rd Ukraine Conference on Electrical and Computer Engineering (UKRCON), Lviv, August 26-28, 2021. 2021. Pp. 530-534. | en |
| dc.relation.ispartof | 2021 IEEE 3rd Ukraine Conference on Electrical and Computer Engineering (UKRCON), Lviv, Ukraine, 2021 : 530-534. | en |
| dc.identifier.doi | 10.1109/UKRCON53503.2021.9575861 | |
| dc.identifier.uri | https://ir.lib.vntu.edu.ua/handle/123456789/46267 | |
| dc.description.abstract | Основними характеристиками волоконно-оптичних мереж, за якими можна вести статистику, прогнозувати втрати під час поширення сигналу лініями зв'язку, встановлювати наявність несанкціонованого доступу до мережі, є потужність оптичного сигналу на виході передавача та вході приймача відповідно і коефіцієнт бітових помилок. Його значення визначається як відношення помилково декодованих бітів до загальної кількості переданих бітів. За вказаними характеристиками це можливо. Наявні методи запобігають основним методам НД до оптичного волокна, але характеризуються низькою точністю встановлення місця несанкціонованого підключення у волоконно-оптичних лініях зв'язку. Запропонований метод контролю волоконно-оптичних ліній зв'язку ґрунтується на одночасному використанні апаратних і програмних засобів, що дає змогу підвищити захищеність інформаційних потоків за рахунок додаткової обробки інформаційних сигналів, які передаються волоконно-оптичними лініями зв'язку, та збільшити достовірність і точність визначення місця несанкціонованого доступу до оптичних каналів. Цей аргумент підтверджує своєчасність і актуальність наукової та практичної проблеми, розв'язання якої потребує розроблення методів і практичних положень для побудови засобів контролю несанкціонованого доступу у волоконно-оптичних лініях зв'язку. | uk |
| dc.description.abstract | he main characteristics of fiber-optic networks for which you can keep statistics, predict losses in signal propagation by communication lines, establish the presence of unauthorized access to the network are the power of the optical signal at the transmitter output and receiver input, respectively, and bit error rate. Its value is defined as the ratio of error-decoded bits to the total number of bits transmitted. According to the specified characteristics it is possible. Existing methods prevent the main methods of ND to optical fiber, but are characterized by low accuracy of establishing the location of unauthorized connection in fiberoptic communication lines. The proposed method of control of fiber-optic communication lines is based on the simultaneous use of hardware and software, which allows to increase the protection of information flows through additional processing of information signals transmitted in fiber-optic communication lines and increase the reliability and accuracy of location unauthorized access to optical channels. This argument confirms the timeliness and relevance of the scientific and practical problem, the solution of which requires the development of methods and practical provisions for the construction of means of control of unauthorized access in fiber-optic communication lines | en |
| dc.subject | bit error rate | en |
| dc.subject | fiber optic transmission system | en |
| dc.subject | communication line | en |
| dc.subject | unauthorized access | en |
| dc.subject | tight wavelength sealing | en |
| dc.subject | gigabit passive optical network | en |
| dc.subject | optical line terminal | en |
| dc.subject | optical network device | en |
| dc.subject | passive optical network | en |
| dc.subject | коефіцієнт бітових помилок | uk |
| dc.subject | волоконно-оптична система передачі | uk |
| dc.subject | лінія зв’язку | uk |
| dc.subject | несанкціонований доступ | uk |
| dc.subject | щільне спектральне ущільнення | uk |
| dc.subject | гігабітна пасивна оптична мережа | uk |
| dc.subject | оптичний лінійний термінал | uk |
| dc.subject | оптичний мережевий пристрій | uk |
| dc.subject | пасивна оптична мережа | uk |
| dc.type | Article, Scopus-WoS | |
| dc.type | Article | |
| dc.language.iso | en | en |
| dc.date.accessioned | 2025-04-10T11:46:42Z | |
| dc.date.available | 2025-04-10T11:46:42Z |