<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Визначення оптимальних значень параметрів керованих компенсувальних пристроїв реактивної потужності магістральних електричних мереж

dc.contributor.authorKuznetsov, V. G.en
dc.contributor.authorKuchansky, V. V.en
dc.contributor.authorTugai, Yu. I.en
dc.contributor.authorSabarno, L. R.en
dc.contributor.authorTugai, I. Yu.en
dc.date.accessioned2026-04-14T12:20:21Z
dc.date.available2026-04-14T12:20:21Z
dc.date.issued2025
dc.description.abstractCreation of large electrical energy systems and their integration raises the problem of transmitting electrical energy to long and extra-long distances, using the technologies of long-distance power transmission. Trends in the development of modern power industry in Ukraine were set forth in the Energy Strategy of Ukraine for the period until 2035, it was stipulated to integrate energy system of Ukraine with the energy system of continental Europe. This occurred on March 16, 2022. Synchronization of the Ukrenergo grid and the energy grid of continental Europe ENTSO-E will allow Ukraine and Europe to develop the energy market, switch to renewable energy sources and boost the European energetic security. The length of the electrical lines in Ukraine is large and their voltage change schedules cause voltage increase above the nominal value in the minimum voltage mode due to the excess reactive power, generated the transmission lines. In this connection there are significant losses of power, forced switching of the equipment and aging of the insulation. UHV transmission lines are very and their phases are executed with the splitting of wires into several components (to reduce corona costs ). Such lines are sources of increased reactive power that depends on power transmission mode and change over a wide range of values, leading to unacceptable voltage fluctuations in the grid , to losses growth (at voltage decrease), to the risk of the equipment damage (in case of its increase). They perform the important role the essential role of the main, system-creating, interstate lines and, therefore, in case of need, they can be used to transmit significant power with the adequate reserve of sustainability. The most effective way to compensate reactive power, maintain the necessary level of voltage in UHV transmission lines and reduce costs the use of shunt reactors (SR). Ukraine has a large territory with a very unequal distribution of energy resources and electric energy consumers. The priority direction of the development of Ukraine’s energy sector is complete integration into European energy market, as it is enshrined in the country’s energy strategy for the period until 2035. This provides the synchronous operation of the integrated energy system (IES) of Ukraine with the energy system of the synchronous zone of the continental Europe ENTSO-E. An important role in the solution of this problem is the provision of the necessary technical state and requirements, regarding the operation modes of main electric lines, grids and interstate power transmission lines (PTL).en
dc.identifier.citationКузнецов В. Г., Кучанський В. В., Тугай Ю. І., Сабарно Л. Р., Тугай І. Ю. Визначення оптимальних значень параметрів керованих компенсувальних пристроїв реактивної потужності магістральних електричних мереж // Вісник Вінницького політехнічного інституту. 2025. № 4. С. 58-66. URI: https://visnyk.vntu.edu.ua/index.php/visnyk/article/view/3303.uk
dc.identifier.doihttps://doi.org/10.31649/1997-9266-2025-181-4-58-66
dc.identifier.issn1997-9274
dc.identifier.udc681.316.1
dc.identifier.urihttps://ir.lib.vntu.edu.ua/handle/123456789/51147
dc.language.isouk_UAuk_UA
dc.publisherВінницький національний технічний університетuk
dc.relation.ispartofВісник Вінницького політехнічного інституту. № 4 : 58-66.uk
dc.relation.referencesS. Sreejith, S. P. Simon, and M. P. Selvan, “Analysis of FACTS devices on security constrained unit commitment prob-lem,” International Journal of Electrical Power & Energy Systems, no. 66, pp. 280-293, 494, 2015.en
dc.relation.referencesZ. Luburi, and I. H. Pand, “FACTS devices and energy storage in unit commitment,”International Journal of Electrical Power & Energy Systems, no. 104, pp. 311-325, 496, 2019.en
dc.relation.referencesM. A. Taher, et al., “Optimal power flow solution incorporating a simplified UPFC model using lightning attachment procedure optimization,”International Transactions on Electrical Energy Systems, no. 30(1), pp. 1-25, 2020.en
dc.relation.referencesSha Jiangbo, et al., “A quantitative index to evaluate the commutation failure probability of LCCHVDC with a synchro-nous condenser,” Applied Sciences, no. 9(5), pp. 925, 500, 2019.en
dc.relation.referencesJ. L. Liu, et al. “Modeling and analysis for global and local power flow operation rules of UPFC embedded system under typical operation conditions,” IEEE Access, no. 8, pp. 21728-21741, 502, 2020.en
dc.relation.referencesH. F. Wang, “Interactions and multivariable design of multiple control functions of a unified power flow controller,” In-ternational Journal of Electrical Power & Energy Systems, no. 24(7), pp. 591-600, 504, 2002.en
dc.relation.referencesV. Kuchanskyy, D. Malakhatka, V. Dumenko, N. Denissova, and B. Yeraliyeva, “Assessment of the phase-by-phase transmis-sion line effect asymmetry on power transfer capability in open phase mode”. Przeglad Elektrotechniczny, vol. 9, pp. 50-53, 2021.en
dc.relation.referencesI. V. Blinov, I. O. Zaitsev, and V. V. Kuchanskyy, Problems, methods and means of monitoring power losses in overhead transmission lines. Systems, Decision and Control in Energy. I, Ed. V. P. Babak, V. Isaienko, A. O. Zaporozhets. Springer, 2020, pp. 123-136.en
dc.relation.referencesV. V. Kuchanskyy, D. O. Malakhatka, and I. V. Blinov,Efficiency increase of open phase modes in bulk electrical net-works. Systems, Decision and Control in Energy. II, Ed. V. P. Babak, V. Isaienko, A. O. Zaporozhets. Springer, 2021, pp. 31-48.en
dc.relation.urihttps://visnyk.vntu.edu.ua/index.php/visnyk/article/view/3303
dc.subjecthigh-voltage power linesen
dc.subjectintermediate systemsen
dc.subjectceramic shunt reactorsen
dc.subjectreactive power balanceen
dc.subjectoptimization of operating modesen
dc.titleВизначення оптимальних значень параметрів керованих компенсувальних пристроїв реактивної потужності магістральних електричних мережuk
dc.title.alternativeDetermination of the Optimal Values of the Parameters of the Controlled Compensating Devices of the Reactive Power of Main Electrical Networksen
dc.typeArticle, professional native edition
dc.typeArticle

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
191672.pdf
Розмір:
398,07 KB
Формат:
Adobe Portable Document Format

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
license.txt
Розмір:
129 B
Формат:
Plain Text
Опис: