<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Система прямого керування струмом активного фільтра

Вантажиться...
Ескіз

Дата

Назва журналу

Номер ISSN

Назва тому

Анотація

The main direction of research is the optimization of the active filter, simplification of the control system and the identifi-cation of new algorithms for calculating the compensating currents. There has been improved the direct current control system of active filter with the formation of sinusoidal signals equal to the fundamental harmonic of phase load currents, as well as non-sinusoidal asymmetric signals, as the difference between input phase currents of load and fundamental harmon-ics, to filter higher harmonics and balancing currents filtering of higher harmonics and balancing of nonlinear asymmetric loads. The control system, which consists of two units: the unit for generating the current compensation of higher harmonics and the unit for converting currents the phase coordinate system to the coordinate system of instantaneous symmet-rical components, provides almost complete compensation for linear and nonlinear distortion. In the case of using one unit for converting currents the phase coordinate system to the coordinate system of instantaneous symmetrical compo-nents, which significantly simplifies the implementation of the control system, provides sufficient for mass consumers quality compensation of higher harmonics (provides compensation of the third, fifth, seventh and ninth current harmonics , and the level of uncompensated higher harmonics is determined by the eleventh and thirteenth harmonics, the content of which is significantly lower) and full load balancing. It is shown that the system of direct current control of the active filter in the case of using the vector of phase currents and the vector of phase voltages can be used for full compensation of reactive power. In this case, there is a slight initial overregulation of the reactive power, which is automatically compensated. The reactive power is regulated indirectly by the voltage support circuit on the capacitor of the active filter voltage inverter.

Опис

Тип документа

Мова

Бібліографічний опис

Бурбело М. Й. Система прямого керування струмом активного фільтра [Текст] / М. Й. Бурбело, Ю. В. Лобода, Д. Ю. Лебедь // Вісник ВПІ. – 2021. – № 2. – С. 69-75.

Схвалення

Рецензія

Доповнено

Цитується в

Список використаної літератури (6)

  1. H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous power theory and applications to power conditioning, IEEE Press, Willy-Interscience, 2007.
  2. H. Akagi, “Active harmonic filters,” Proceedings of the IEEE, vol. 93, № 12, рp. 2128-2141, 2005.
  3. Н. Akagi, “Modern Active Filters and Traditional Passive Filters,” Bulletin of the Polish Academy of Science, Technical Sciences, vol. 54, pp. 255-269, 2006.
  4. F. Z. Peng, and J. S. Lai, “Generalized instantaneous reactive power theory of three-phase power systems,” IEEE Trans. Instrum. Meas, vol. 45, № 1, pp. 293-297, 1996.
  5. J. C. Montano, P. Salmeron, and J. P. Thomas, “Analysis of Power Losses for Instantaneous Compensation of ThreePhase Four-Wire System,” IEEE Trans. Power Electron, vol. 20, № 4, pp. 901-907, 2005.
  6. J. C. Montano, and P. Salmeron, “Compensation in nonsinusoidal, unbalanced three-phase four-wire systems with active power-line conditioner,” IEEE Trans. Power Delivery, vol. 17, № 4, рp. 1079-1084, 2002.