<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Джонс-матрична реконструкція оптичної анізотропії плівок біологічних рідин в інтелектуалізованій системі поляризаційної інтроскопії при оцінюванні патологій

Анотація

The article considers the method of Jones-matrix polarization reconstruction of two-dimensional distributions of linear and circular dichroism of dehydrated films of biological fluids based on intensity measurements, which is used as the basis for assessing pathologies in an intelligent polarization introscopy system. Multiparametric analysis of measured maps based on wavelet transform, statistical processing and fuzzy classification models is applied. An increase in the reliability of assessing the "normal"-"pathological" states in the system was achieved due to multiparametric intellectualized analysis compared to analogues by 1.5%-1.7%, depending on the scale coefficients of the wavelet transform.
В статті розглянуто метод Джонс-матричної поляризаційної реконструкції двовимірних розподілів лінійного та циркулярного дихроїзму дегідратованих плівок біологічних рідин на основі вимірювання інтенсивностей, покладений в основу оцінювання патологій в інтелектуалізованій системі поляризаційної інтроскопії. Застосовується багатопараметричний аналіз виміряних мап на основі вейвлет-перетворення, статистичного оброблення та нечітких класифікаційних моделей. Досягнуто підвищення достовірності оцінювання станів «норма»-«патологія» в системі за рахунок багатопараметричного інтелектуалізованого аналізу в порівнянні із аналогами на 1,5%-1,7% в залежності від масштабних коефіцієнтів вейвлет-перетворення.

Опис

Мова

Бібліографічний опис

Шолота В. В. Джонс-матрична реконструкція оптичної анізотропії плівок біологічних рідин в інтелектуалізованій системі поляризаційної інтроскопії при оцінюванні патологій // Оптико-електроннi iнформацiйно-енергетичнi технологiї. 2026. № 1. С. 235-242. URI: https://oeipt.vntu.edu.ua/index.php/oeipt/article/view/847.

Схвалення

Рецензія

Доповнено

Цитується в

Список використаної літератури (18)

  1. Ushenko V. A., Dubolazov O. V., Karachevtsev A. O., “Two wavelength Mueller matrix reconstruction of blood plasmafilms polycrystalline structure in diagnostics of breast cancer,” Applied Optics. 53(10), B128-B139 (2014).
  2. Prysyazhnyuk V. P., Ushenko Yu. A., Dubolazov A. V., Ushenko A. G., and Ushenko V. A., "Polarization-dependentlaser autofluorescence of the polycrystalline networks of blood plasma films in the task of liver pathologydifferentiation," Appl. Opt. 55, B126-B132 (2016).
  3. Dubolazov A.V. Pashkovskaya N.V., Ushenko Yu.A., Marchuk Yu.F., Ushenko V.A., Novakovskaya O.Yu,“Birefringence images of polycrystalline films of human urine in early diagnostics of kidney pathology, ” AppliedOptics. 55 (12), B85-B90 (2016).
  4. Zabolotna, N.I., Sholota, V.V., Okarskyi H.H., “Methods and systems of polarization reproduction and analysis of thebiological layers structure in the diagnosis of pathologies,” Proceedings of SPIE. 11369, 113691S, P. 501-513 (2020).
  5. Sieryi O., Ushenko Yu., Ushenko V., Dubolazov J., et al., “Optical anisotropy composition of benign and malignantprostate tissues revealed by Mueller-matrix imaging,” Biomed. Opt. Express 13(11), 6019–6034 (2022).
  6. Vasyuk, V.L., Kalashnikov, A.V., Ushenko, A.G. et al., “Digital Information Methods of Polarization, Mueller-Matrixand Fluorescent Microscopy”, Springer Nature Singapore, 2023. 102 p.
  7. Jiao, S., Wang, L. V. “Jones-matrix imaging of biological tissues with quadruple-channel optical coherencttomography,” J. Biomed. Opt. 7(3), pp. 350–358 (2002) doi: 10.1117/1.1483878.
  8. Jones. C.R. “New calculus for the treatment of optical systems. VII. Properties of the N-matrices,” J. Opt. Soc. Am. 38,671-685, 1948.
  9. Azzam R.M.A., “ Propagation of partially depolarized light through anisotropic media with or without depolarization. Adifferential 4x4 matrix calculus,” J.Opt.Soc.Am., 68, 1756-1767, 1978.
  10. Arteaga O., Canillas A., "Analytic inversion of the Mueller-Jones polarization matrices for homogeneous media," Opt.Lett. 35, 559-561 (2010).