dc.identifier.citationOptical method to determine the quantity of water in milk using the visible radiation range [Electronic resource] / V. Kucheruk, P. Kulakov, O. Vasilevskyi [etc.] // Proceedings of SPIE. Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2018. – 2018. – Vol. 10808. – 108082Y1-8. – DOI: https://doi.org/10.1117/12.2501605.uk
dc.identifier.citationKucheruk V., Kulakov P., Vasilevskyi O., Mostovyi D., Kulakova A., Kobylyanska I., Karnakova G., Kisała P. Optical method to determine the quantity of water in milk using the visible radiation range. Proceedings of SPIE. Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2018. 2018. Vol. 10808. DOI: https://doi.org/10.1117/12.2501605.en
dc.identifier.urihttp://ir.lib.vntu.edu.ua//handle/123456789/31810
dc.description.abstractAn optical method for determine the quantity of water in milk using the visible optical radiation range is proposed. On the basis of theoretical and experimental studies of the water-milk solution spectral characteristics the proposed method mathematical model was created. The mathematical modeling of passing of the visible range optical radiation through a water-milk solution on certain thickness of the solution layer is carried out. As a result of the modeling, the dependence of the output voltage of the photoreceiver based on a pair of photodiode-operating amplifier the relative mass fraction of milk in the water-milk solution and the wavelength of the optical radiation in the visible range is obtained.en
dc.language.isouk_UAuk_UA
dc.publisherInternational Society for Optics and Photonicsen
dc.relation.ispartofProceedings of SPIE. Photonics Applications in Astronomy, Communications, Industry, and High-Energy Physics Experiments 2018. Vol. 10808 : 108082Y.en
dc.titleOptical method to determine the quantity of water in milk using the visible radiation rangeen