Різниця в роботі бурових і забивних паль за результатами фізичного моделювання
Abstract
A static load test of small-scale models of driven and bored piles with a change in length in conditions of homogeneous soil was carried out. The bearing capacity of the piles was calculated using the method recommended by the current standards of Ukraine [1].
It was established that the real bearing capacity of bored and driven piles differs that calculated using the methods recommended by the current regulatory documents [1].
The purpose of this work is to compare the operation of driven and bored piles under load in small-scale physical modeling.
Based on the results of small-scale physical modeling, the difference in the operation of bored and driven piles was established, and the inaccuracy of analytical calculations of the bearing capacity of piles was confirmed and indicates the complex processes of pile-soil interaction. Проведено випробування статичним навантаженням маломасштабних моделей забивних та бурових паль зі зміною довжини в умовах однорідного ґрунту. Виконаний розрахунок несучої здатності паль за методикою, що рекомендована чинними нормами України [1].
Встановлено, що реальна несуча здатність бурових та забивних паль відрізняється від розрахованої за методами, що рекомендовані чинними нормативними документами [1].
Метою даної роботи є порівняння роботи забивних та бурових паль під навантаженням на маломосштабному фізичному моделюванні.
На основі результатів мало масштабного фізичного моделювання встановлено різницю у роботі бурових та забивних паль, а також підтверджено неточність аналітичних розрахунків несучої здатності паль та вказує на складні процеси взаємодії палі з ґрунтом.