Показати скорочену інформацію

dc.contributor.authorPavlov, V. S.en
dc.contributor.authorZabolotna, N. I.en
dc.contributor.authorShtofel, D. Kh.en
dc.contributor.authorYang Longyinen
dc.contributor.authorKomarova, O. S.en
dc.contributor.authorKaduk, O. V.en
dc.contributor.authorПавлов, В. С.uk
dc.contributor.authorЗаболотна, Н. І.uk
dc.contributor.authorШтофель, Д. Х.uk
dc.contributor.authorЯн, Луніньuk
dc.contributor.authorКомарова, О. С.uk
dc.contributor.authorКадук, О. В.uk
dc.date.accessioned2024-11-22T13:12:02Z
dc.date.available2024-11-22T13:12:02Z
dc.date.issued2024
dc.identifier.citationPavlov S. V., Zabolotna N. I., Shtofel D. Kh., Yang L., Komarova O. S., Kaduk O. V. Realization of a laser fiber-optical device for assessing tissue microcirculation // Оптико-електроннi iнформацiйно-енергетичнi технологiї. 2024. № 2 (48). С. 205–211.en, uk
dc.identifier.issn1681-7893
dc.identifier.urihttps://ir.lib.vntu.edu.ua//handle/123456789/43611
dc.description.abstractThe main goal of this study was to carry out research leading to an increase in the reliability of diagnosing the state of peripheral blood circulation by improving the methods of recording optical radiation and using optical-electronic means for the analysis of photoplethysmographic information. Based on the results of the study, we designed a fiber-optic device for diagnosing tissue microcirculation, ensuring miniaturization of the sensitive element of the fiber-optic sensor, and the possibility of monitoring, diagnosing, and screening the state of tissue microcirculation in various optical modes and conditions with high reliability.en
dc.description.abstractОсновною метою даної роботи було проведення досліджень, спрямованих на підвищення достовірності діагностики стану периферичного кровообігу шляхом вдосконалення методів реєстрації оптичного випромінювання та використання оптико-електронних засобів аналізу фотоплетизмографічної інформації. За результатами дослідження створено волоконно-оптичний пристрій для діагностики мікроциркуляції тканин із забезпеченням мініатюризації конструкції, зокрема чутливого елементу волоконно-оптичного сенсора, можливості проведення контролю, діагностики та скринінгу стану тканинної мікроциркуляції в різних оптичних режимах і умовах з високою надійністю.uk
dc.language.isoenen
dc.publisherВНТУuk
dc.relation.ispartofОптико-електроннi iнформацiйно-енергетичнi технологiї. № 2 : 205–211.uk
dc.relation.urihttps://oeipt.vntu.edu.ua/index.php/oeipt/article/view/743
dc.subjectлазерне випромінюванняuk
dc.subjectспектри пропусканняuk
dc.subjectлазерний волоконно-оптичний пристрійuk
dc.subjectбіологічні тканиниuk
dc.subjectтканинна мікроциркуляціяuk
dc.subjectlaser radiationen
dc.subjecttransmission spectraen
dc.subjectlaser fiber-optic deviceen
dc.subjectbiological tissuesen
dc.subjecttissue microcirculationen
dc.titleRealization of a laser fiber-optical device for assessing tissue microcirculationen
dc.title.alternativeРеалізація лазерного волоконно-оптичного приладу для оцінювання тканинної мікроциркуляціїuk
dc.typeArticle, professional native edition
dc.typeArticle
dc.identifier.udc615.471.03:616.073
dc.relation.referencesBorn M. Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of Light / M. Born, E. Wolf // 6th edn. (corrected). – Pergamon Press, 1986. – Р. 45-113.en
dc.relation.referencesWang X. Polarized light propagation through scattering media: time-resolved Monte Carlo simulations and experiments / X. Wang // Journal of biomedical optics. – 2003. – Т. 8. – №. 4. – С. 608-617.en
dc.relation.referencesWang L. MCML – Monte Carlo modeling of light transport in multi-layered tissues / L. Wang, L. J. Steven, Z. Ligiong // Computer methods and programs in biomedicine. – № 47, 1995. – Р 131–145.en
dc.relation.referencesVan de Hulst H. C. Multiple light scattering: tables, formulas, and applications / H. C. Van de Hulst // Elsevier, reprinted 2012. – Т. 1. 332 pen
dc.relation.referencesPrahl S. A. A Monte Carlo model of light propagation in tissue / S. A. Prahl, M. Keijzer, S. L. Jacques, Welch A. J. Laser Radiat. Med. Biol. – 1989. – vol. 5. – P. 102-11.en
dc.relation.referencesGhosh N. Depolarization of light in a multiply scattering medium: effect of the refractive index of a scatterer / N. Ghosh // Physical Review E. – 2004. – Т. 70. – №. 6. – С. 066607en
dc.relation.referencesZhang R. Determination of human skin optical properties from spectrophotometric measurements based on optimization by genetic algorithms / R. Zhang //Journal of biomedical optics. – 2005. – Т. 10. – №. 2. – С. 024030-02403011.en
dc.relation.referencesAnderson R. Polarized light examination and photography of the skin / R. R. Anderson. // Archives of dermatology. – 1991. – №127. – С. 1000–1005.en
dc.relation.referencesGil J. J. Characteristic properties of Mueller matrices / J. J. Gil // JOSA A. – 2000. – Т. 17. – №. 2. – С. 328-334en
dc.relation.referencesR. U. Rovira, S. V. Pavlov, Monte Carlo simulation for studying the propagation of polarized light in biological tissue / Optical-electronic information and energy technologies. – 2014. – No. 2 (28). – pp. 56-61. – ISSN 1681-7893.en
dc.relation.referencesWójcik, W., Pavlov, S., Kalimoldayev, M. (2019). Information Technology in Medical Diagnostics II. London: Taylor & Francis Group, CRC Press, Balkema book. – 336 Pages, https://doi.org/10.1201/ 9780429057618. eBook ISBN 9780429057618.en
dc.relation.referencesRovira R. H. Particular Aspects of the Use of Videopolarimetric Technology for Dermatological Study, Measuring and computing equipment in technological processes. – 2014. – №. 3 (48). – P. 115-119. – ISSN 2219-9365.en
dc.relation.referencesPavlov S.V., Kozhemiako V.P., Petruk V.G., Kolesnik P.F., “Photoplethysmohrafic technologies of the cardiovascular control”, Vinnitsa: Universum-Vinnitsa, p. 254, (2007).en
dc.relation.referencesWójcik, W., Pavlov, S., Kalimoldayev, M. “Information Technology in Medical Diagnostics II”. London: Taylor & Francis Group, CRC Press, Balkema book, p. 336, (2019).en
dc.relation.referencesPavlov, S.V., Kozhukhar, A. T., “Electro-optical system for the automated selection of dental implants according to their colour matching”, Przegląd elektrotechniczny, ISSN 0033-2097, R. 93 NR 3, 121- 124, (2017)en
dc.relation.referencesZabolotna, N. I.; Pavlov S. V., Radchenko, K. O.; Stasenko, V. A. , Wójcik, W. etc. “Diagnostic efficiency of Mueller-matrix polarization reconstruction system of the phase structure of liver tissue”, Proc. SPIE 9816, Optical Fibers and Their Applications, 98161E, (2015)en
dc.relation.referencesKukharchuk, Vasyl V., Pavlov Sergii V., etc. "Information Conversion in Measuring Channels with Optoelectronic Sensors" Sensors 22, no. 1: 271, (2022).en
dc.relation.referencesKozlovska Tatiana I., Zlepko Sergii M., Kolesnic Petro F., Pavlov Volodymyr S., etc. "Optoelectronic multispectral device for determining the state of peripheral blood circulation", Proc. SPIE 11581, Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2020, 115810L, (2020).en
dc.relation.referencesKanishyna Tetiana, Shkilniak Liudmyla, etc. "Study of tissue microcirculation disorders after tooth extraction by photoplethysmography in diabetic patients", Proc. SPIE 12476, Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2022, 1247603 (12 December 2022).en
dc.identifier.doihttps://doi.org/10.31649/1681-7893-2024-48-2-205-211


Файли в цьому документі

Thumbnail

Даний документ включений в наступну(і) колекцію(ї)

Показати скорочену інформацію