dc.contributor.author | Pavlov, V. S. | en |
dc.contributor.author | Zabolotna, N. I. | en |
dc.contributor.author | Shtofel, D. Kh. | en |
dc.contributor.author | Yang Longyin | en |
dc.contributor.author | Komarova, O. S. | en |
dc.contributor.author | Kaduk, O. V. | en |
dc.contributor.author | Павлов, В. С. | uk |
dc.contributor.author | Заболотна, Н. І. | uk |
dc.contributor.author | Штофель, Д. Х. | uk |
dc.contributor.author | Ян, Лунінь | uk |
dc.contributor.author | Комарова, О. С. | uk |
dc.contributor.author | Кадук, О. В. | uk |
dc.date.accessioned | 2024-11-22T13:12:02Z | |
dc.date.available | 2024-11-22T13:12:02Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Pavlov S. V., Zabolotna N. I., Shtofel D. Kh., Yang L., Komarova O. S., Kaduk O. V. Realization of a laser fiber-optical device for assessing tissue microcirculation // Оптико-електроннi iнформацiйно-енергетичнi технологiї. 2024. № 2 (48). С. 205–211. | en, uk |
dc.identifier.issn | 1681-7893 | |
dc.identifier.uri | https://ir.lib.vntu.edu.ua//handle/123456789/43611 | |
dc.description.abstract | The main goal of this study was to carry out research leading to an increase in the reliability of diagnosing the state of peripheral blood circulation by improving the methods of recording optical radiation and using optical-electronic means for the analysis of photoplethysmographic information. Based on the results of the study, we designed a fiber-optic device for diagnosing tissue microcirculation, ensuring miniaturization of the sensitive element of the fiber-optic sensor, and the possibility of monitoring, diagnosing, and screening the state of tissue microcirculation in various optical modes and conditions with high reliability. | en |
dc.description.abstract | Основною метою даної роботи було проведення досліджень, спрямованих на підвищення достовірності діагностики стану периферичного кровообігу шляхом вдосконалення методів реєстрації оптичного випромінювання та використання оптико-електронних засобів аналізу фотоплетизмографічної інформації. За результатами дослідження створено волоконно-оптичний пристрій для діагностики мікроциркуляції тканин із забезпеченням мініатюризації конструкції, зокрема чутливого елементу волоконно-оптичного сенсора, можливості проведення контролю, діагностики та скринінгу стану тканинної мікроциркуляції в різних оптичних режимах і умовах з високою надійністю. | uk |
dc.language.iso | en | en |
dc.publisher | ВНТУ | uk |
dc.relation.ispartof | Оптико-електроннi iнформацiйно-енергетичнi технологiї. № 2 : 205–211. | uk |
dc.relation.uri | https://oeipt.vntu.edu.ua/index.php/oeipt/article/view/743 | |
dc.subject | лазерне випромінювання | uk |
dc.subject | спектри пропускання | uk |
dc.subject | лазерний волоконно-оптичний пристрій | uk |
dc.subject | біологічні тканини | uk |
dc.subject | тканинна мікроциркуляція | uk |
dc.subject | laser radiation | en |
dc.subject | transmission spectra | en |
dc.subject | laser fiber-optic device | en |
dc.subject | biological tissues | en |
dc.subject | tissue microcirculation | en |
dc.title | Realization of a laser fiber-optical device for assessing tissue microcirculation | en |
dc.title.alternative | Реалізація лазерного волоконно-оптичного приладу для оцінювання тканинної мікроциркуляції | uk |
dc.type | Article, professional native edition | |
dc.type | Article | |
dc.identifier.udc | 615.471.03:616.073 | |
dc.relation.references | Born M. Principles of Optics: Electromagnetic Theory of Propagation, Interference and Diffraction of
Light / M. Born, E. Wolf // 6th edn. (corrected). – Pergamon Press, 1986. – Р. 45-113. | en |
dc.relation.references | Wang X. Polarized light propagation through scattering media: time-resolved Monte Carlo simulations
and experiments / X. Wang // Journal of biomedical optics. – 2003. – Т. 8. – №. 4. – С. 608-617. | en |
dc.relation.references | Wang L. MCML – Monte Carlo modeling of light transport in multi-layered tissues / L. Wang,
L. J. Steven, Z. Ligiong // Computer methods and programs in biomedicine. – № 47, 1995. – Р 131–145. | en |
dc.relation.references | Van de Hulst H. C. Multiple light scattering: tables, formulas, and applications / H. C. Van de Hulst //
Elsevier, reprinted 2012. – Т. 1. 332 p | en |
dc.relation.references | Prahl S. A. A Monte Carlo model of light propagation in tissue / S. A. Prahl, M. Keijzer, S. L. Jacques,
Welch A. J. Laser Radiat. Med. Biol. – 1989. – vol. 5. – P. 102-11. | en |
dc.relation.references | Ghosh N. Depolarization of light in a multiply scattering medium: effect of the refractive index of a
scatterer / N. Ghosh // Physical Review E. – 2004. – Т. 70. – №. 6. – С. 066607 | en |
dc.relation.references | Zhang R. Determination of human skin optical properties from spectrophotometric measurements based
on optimization by genetic algorithms / R. Zhang //Journal of biomedical optics. – 2005. – Т. 10. –
№. 2. – С. 024030-02403011. | en |
dc.relation.references | Anderson R. Polarized light examination and photography of the skin / R. R. Anderson. // Archives of
dermatology. – 1991. – №127. – С. 1000–1005. | en |
dc.relation.references | Gil J. J. Characteristic properties of Mueller matrices / J. J. Gil // JOSA A. – 2000. – Т. 17. – №. 2. –
С. 328-334 | en |
dc.relation.references | R. U. Rovira, S. V. Pavlov, Monte Carlo simulation for studying the propagation of polarized light in
biological tissue / Optical-electronic information and energy technologies. – 2014. – No. 2 (28). – pp.
56-61. – ISSN 1681-7893. | en |
dc.relation.references | Wójcik, W., Pavlov, S., Kalimoldayev, M. (2019). Information Technology in Medical Diagnostics II.
London: Taylor & Francis Group, CRC Press, Balkema book. – 336 Pages, https://doi.org/10.1201/
9780429057618. eBook ISBN 9780429057618. | en |
dc.relation.references | Rovira R. H. Particular Aspects of the Use of Videopolarimetric Technology for Dermatological Study,
Measuring and computing equipment in technological processes. – 2014. – №. 3 (48). – P. 115-119. –
ISSN 2219-9365. | en |
dc.relation.references | Pavlov S.V., Kozhemiako V.P., Petruk V.G., Kolesnik P.F., “Photoplethysmohrafic technologies of the
cardiovascular control”, Vinnitsa: Universum-Vinnitsa, p. 254, (2007). | en |
dc.relation.references | Wójcik, W., Pavlov, S., Kalimoldayev, M. “Information Technology in Medical Diagnostics II”.
London: Taylor & Francis Group, CRC Press, Balkema book, p. 336, (2019). | en |
dc.relation.references | Pavlov, S.V., Kozhukhar, A. T., “Electro-optical system for the automated selection of dental implants
according to their colour matching”, Przegląd elektrotechniczny, ISSN 0033-2097, R. 93 NR 3, 121-
124, (2017) | en |
dc.relation.references | Zabolotna, N. I.; Pavlov S. V., Radchenko, K. O.; Stasenko, V. A. , Wójcik, W. etc. “Diagnostic
efficiency of Mueller-matrix polarization reconstruction system of the phase structure of liver tissue”,
Proc. SPIE 9816, Optical Fibers and Their Applications, 98161E, (2015) | en |
dc.relation.references | Kukharchuk, Vasyl V., Pavlov Sergii V., etc. "Information Conversion in Measuring Channels with
Optoelectronic Sensors" Sensors 22, no. 1: 271, (2022). | en |
dc.relation.references | Kozlovska Tatiana I., Zlepko Sergii M., Kolesnic Petro F., Pavlov Volodymyr S., etc. "Optoelectronic
multispectral device for determining the state of peripheral blood circulation", Proc. SPIE 11581,
Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics
Experiments 2020, 115810L, (2020). | en |
dc.relation.references | Kanishyna Tetiana, Shkilniak Liudmyla, etc. "Study of tissue microcirculation disorders after tooth
extraction by photoplethysmography in diabetic patients", Proc. SPIE 12476, Photonics Applications in
Astronomy, Communications, Industry, and High Energy Physics Experiments 2022, 1247603 (12
December 2022). | en |
dc.identifier.doi | https://doi.org/10.31649/1681-7893-2024-48-2-205-211 | |