| dc.contributor.author | Biks, Y. | en |
| dc.contributor.author | Ratushniak, O. | en |
| dc.contributor.author | Бікс, Ю. | uk |
| dc.contributor.author | Ратушняк, О. | uk |
| dc.date.accessioned | 2026-07-08T12:56:44Z | |
| dc.date.available | 2026-07-08T12:56:44Z | |
| dc.date.issued | 2026 | |
| dc.identifier.citation | Biks Y., Ratushniak O. Dynamic performance assessment of multilayered wall assemblies // Сучасні технології, матеріали і конструкції в будівництві. 2026. № 1. С. 185-195. URI: https://stmkvb.vntu.edu.ua/index.php/stmkvb/article/view/999. | en |
| dc.identifier.issn | 2311-1437 | |
| dc.identifier.uri | https://ir.lib.vntu.edu.ua//handle/123456789/52192 | |
| dc.description.abstract | This paper introduces an approach to assessing the dynamic performance of multilayered building envelopes, focusing on physically measurable thermal performance metrics. Based on EN ISO 13786:2023, the study considers thermal transmittance (U-value), internal areal heat capacity (k1), and decrement factor (f) as thermal performance parameters, and wall mass as an additional objective indicator. Five wall assemblies common in the Ukrainian market - hempcrete, AAC + Rockwool, Porotherm brickwork + Rockwool, wood-chip cement-bonded blocks (Woodcrete) and ICF systems were evaluated through numerical modelling and comparative analysis. To eliminate subjectivity in the weighting of criteria, the four physically meaningful parameters are compared to determine the overall assessment. Results indicate that Wall E (ICF) ranks as the dynamically balanced, efficient assembly according to the internal area heat capacity and decrement factor parameters, but it has the maximum mass among other assemblies. Wall B (AAC) demonstrated the highest heat-flux attenuation effect, 0.115, which can lead to summer overheating, while Wall C (hollow brick + insulator) and Wall D (Woodcrete) demonstrated a similar dynamic behaviour with a too-low decrement factor, 0.007. The study highlights the complexity of MCDA in envelope design and provides physically grounded criteria that can support more objective predesign decision-making. Current research revealed that, even though all the walls meet the requirements of the Ukrainian National Building Code, steady-state thermal transmittance coefficient (U-value) can be considered only in the early stages of decision-making as the primary determinant of envelope efficiency; however, this parameter alone fails to accurately reflect the dynamic thermal behaviour of constructions and their inertia-related performance. | en |
| dc.description.abstract | У цій статті представлено підхід до оцінки динамічних характеристик багатошарових огороджувальних конструкцій будівель, зосереджуючись на фізично вимірюваних показниках теплотехнічних характеристик. На основі стандарту EN ISO 13786:2023 у дослідженні розглядаються коефіцієнт теплопередачі (U-value), внутрішня питома теплоємність (k1) та коефіцієнт загасання (f) як параметри теплових характеристик, а маса стіни як додатковий об&039;єктивний показник. П&039;ять стінових конструкцій, поширених на українському ринку - конопляний бетон (Костробетон), газобетон + мінеральна вата, цегляна кладка Porotherm + мінеральна вата, деревно-стружкові цементно-зв&039;язані блоки (Арболіт) та системи ICF (Блоки незйомної опалубки) - були оцінені за допомогою числового моделювання та порівняльного аналізу. Щоб усунути суб&039;єктивність у зважуванні критеріїв, чотири фізично значущі параметри порівнюються для визначення загальної оцінки. Результати показують, що стіна E (ICF) вважається динамічно збалансованою, ефективною конструкцією відповідно до параметрів внутрішньої питомої теплоємності та коефіцієнта загасання, проте вона має найбільшу масу серед інших конструкцій. Стіна B (Газобетон) продемонструвала найвищий ефект ослаблення теплового потоку – 0,115, що може призвести до літнього перегріву, тоді як стіна C (Порожниста цегла + утеплювач) та стіна D (Арболіт) показали подібну динамічну поведінку з надто низьким коефіцієнтом загасання – 0,007. Дослідження підкреслює складність об&039;єктивного багатокритеріального аналізу без вдавання до маніпуляцій з даними щодо проєктування огороджувальних конструкцій та надає фізично обґрунтовані критерії, які можуть сприяти більш об&039;єктивному прийняттю передпроєктних рішень. Поточні дослідження показали, що, хоча всі стіни відповідають вимогам ДБН України, стаціонарний коефіцієнт теплопередачі (U-value) можна розглядати лише на ранніх етапах прийняття рішень як ключовий параметр енергоефективності огороджувальної конструкції; однак, цей параметр сам по собі не може точно відобразити динамічну теплову поведінку конструкцій та їх інерційні характеристики. | uk |
| dc.language.iso | en_US | en_US |
| dc.publisher | ВНТУ | uk |
| dc.relation.ispartof | Сучасні технології, матеріали і конструкції в будівництві. № 1 : 185-195. | uk |
| dc.relation.uri | https://stmkvb.vntu.edu.ua/index.php/stmkvb/article/view/999 | |
| dc.subject | динамічні теплові характеристики | uk |
| dc.subject | багатошарова конструкція | uk |
| dc.subject | оболонки | uk |
| dc.subject | енергоефективність | uk |
| dc.subject | фізичні параметри | uk |
| dc.subject | Dynamic thermal performance | en |
| dc.subject | Multilayered assembly | en |
| dc.subject | Envelopes | en |
| dc.subject | Energy efficiency | en |
| dc.subject | Physical parameters | en |
| dc.title | Dynamic performance assessment of multilayered wall assemblies | en |
| dc.title.alternative | Порівняння динамічних характеристик енергоефективних багатошарових огороджувальних конструкцій | uk |
| dc.type | Article, professional native edition | |
| dc.type | Article | |
| dc.identifier.udc | 699.86:697.1 | |
| dc.relation.references | J. Kosny, E. Kossecka, A. O. Desjarlais, and J. E. Christian, “Dynamic thermal performance of concrete and masonry walls,” in Buildings VII: Thermal Performance of Exterior Envelopes of Whole Buildings, Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), 1998. | en |
| dc.relation.references | E. Kossecka and J. Kosny, “Equivalent wall as a dynamic model of a complex thermal structure,” Journal of Thermal Insulation and Building Envelopes, vol. 20, no. 3, pp. 249–268, 1997, doi: 10.1177/109719639702000306. | en |
| dc.relation.references | P. Shafigh, I. Asadi, and N. B. Mahyuddin, “Concrete as a thermal mass material for building applications -A review,” Journal of Building Engineering, vol. 19, pp. 14–25, Sep. 2018, doi: 10.1016/j.jobe.2018.04.021. | en |
| dc.relation.references | Stazi, F. (2017). Thermal Inertia in Energy Efficient Building Envelopes. Butterworth-Heinemann. https://doi.org/10.1016/C2016-0-00641-1. | en |
| dc.relation.references | A. H. Ghoreishi and M. M. Ali, “Contribution of Thermal Mass to Energy Performance of Buildings: A Comparative Analysis,” International Journal of Sustainable Building Technology and Urban Development, vol. 2, no. 3, pp. 245–252, Sep. 2011, doi: 10.5390/susb.2011.2.3.245. | en |
| dc.relation.references | Humaish, H.H., Marmoret, L., & Beji, H. (2018). Effect of thermal inertia (time lag and decrement factor) on the insulation thermal capacity. 2018 International Conference on Advance of Sustainable Engineering and its Application (ICASEA), 137-141. https://doi.org/10.1109/icasea.2018.8370971. | en |
| dc.relation.references | Childs, K. W., Courville, G. E., & Bales, E. L. (1983). Thermal mass assessment: an explanation of the mechanisms by which building mass influences heating and cooling energy requirements (No. ORNL/CON-97). Oak Ridge National Lab.(ORNL), Oak Ridge, TN (United States). https://doi.org/10.2172/5788833. | en |
| dc.relation.references | Kalinović, S. M., Djoković, J. M., Nikolić, R. R., & Hadzima, B. (2019). Calculation of the thermal dynamic performance of the residential buildings' walls. Quality Production Improvement-QPI, 1. | en |
| dc.relation.references | Alkhatib, H., & Lemarchand, P. (2024). Assessing Thermal Performance: An Experimental Study on U-Value Variability in Building Fabric Elements. Results in Engineering. https://doi.org/10.1016/j.rineng.2024.103730. | en |
| dc.relation.references | Verbeke, S., & Audenaert, A. (2018). Thermal inertia in buildings: A review of impacts across climate and building use. Renewable and sustainable energy reviews, 82, 2300-2318. https://doi.org/10.1016/j.rser.2017.08.083. | en |
| dc.relation.references | Oktay, H., Argunhan, Z., Yumrutaş, R., Işık, M. Z., & Budak, N. (2016). An investigation of the influence of thermophysical properties of multilayer walls and roofs on the dynamic thermal characteristics.Mugla Journal of Science and Technology, 2(1), 48-54. | en |
| dc.relation.references | B. Salehpour, M. Ghobadi, T. Moore, and H. Ge, “Component sequence and thermal mass effects on the transient thermal performance of concrete walls,” Journal of Physics: Conference Series, vol. 2069, no. 1, Art. no. 012091, Nov. 2021, doi: 10.1088/1742-6596/2069/1/012091. | en |
| dc.relation.references | Reilly, A., Kinnane, O., & O’Hegarty, R. (2020). Energy embodied in, and transmitted through, walls of different types when accounting for the dynamic effects of thermal mass. Journal of Green Building, 15(4), 43-66. https://doi.org/10.3992/jgb.15.4.43. | en |
| dc.relation.references | Reilly, A., & Kinnane, O. (2017). The impact of thermal mass on building energy consumption. Applied Energy, 198, 108-121. https://doi.org/10.1016/j.apenergy.2017.04.024. | en |
| dc.relation.references | Stazi, F., Ulpiani, G., Pergolini, M., & Di Perna, C. (2018). The role of areal heat capacity and decrement factor in case of hyper insulated buildings: An experimental study. Energy and Buildings, 176, 310-324. https://doi.org/10.1016/j.enbuild.2018.07.034. | en |
| dc.relation.references | Ukrainian National Standard. DSTU EN ISO 13786:2023 Thermal performance of building components –Dynamic thermal characteristics –Calculation methods (2023). (Official edition) Kyiv: Institute of Technical Thermophysics of the National Academy of Sciences of Ukraine (in Ukrainian). | en |
| dc.relation.references | A brief guide and free tool for the calculation of the thermal mass of building components. Retrieved February 18, 2026, from: https://www.htflux.com/en/free-calculation-tool-for-thermal-mass-of-building-components-iso-13786/. | en |
| dc.relation.references | Isotex. (n.d.). Isotex: Wood-cement blocks for construction. Retrieved June 5, 2025, from. https://en.blocchiisotex.com/. | en |
| dc.relation.references | Isotex Srl. (2025) Product catalogue. Retrieved July 19, 2025 from. https://www.blocchiisotex.com/wp-content/uploads/2025/02/product-catalogue-isotex-worldwide.pdf. | en |
| dc.relation.references | Fixolite. (2009). Brochure: Blocs de construction isolants en aggloméré bois-ciment. La performance au service de l’éco-construction [document PDF]. Retrieved June 22, 2025, from http://www.fixolite.be/sites/fixolite.be/files/Brochure_Blocs_Fixolite_ENTETE_VERTEmodif.pdf. | en |
| dc.relation.references | Isospan. (2025). Technical Data and Product Range. Retrieved June 29, 2025, from https://www.isospan.eu/cms/upload/dlmstat/index.php?sprache=en. | en |
| dc.relation.references | Fasswall®. Build your natural, non-toxic home with this remarkable wood-chip concrete building block. Retrieved March 20, 2026, from https://faswall.com. | en |
| dc.relation.references | Nexcem. Insulated Concrete Forms without Styrofoam. Retrieved March 20, 2026, from. https://nexcembuild.com/. | en |
| dc.relation.references | Durisol. DURISOL ICF INSULATED CONCRETE FORMS FOR AUSTRALIA. Retrieved March 20, 2026, from https://www.durisol.com.au/. | en |
| dc.relation.references | Костробетон —революційна новинка на ринку екобудівництва (Hemcrete –a new revolutionary innovation on the ecobuilding maket) Retrieved March 20, 2026, from https://zelenasadyba.com.ua/dim-i-podvirya/kostrobeton.html(in Ukrainian). | en |
| dc.relation.references | Утеплення будинку з газобетону зовні: як правильно це зробити? (House exterior insulation –how to perform it correctly?) Retrieved March 20, 2026, from http://gazobloki.lviv.ua/uteplennya-budinku-z-gazobetonu-zovni-yak-pravilno-ce-zrobiti/ (in Ukrainian). | en |
| dc.relation.references | Porotherm 38 P+W. Retrieved March 20, 2026, from https://info-haus.com/product/porotherm-38-p-w/ (in Ukrainian). | en |
| dc.relation.references | Будинок з арболіта —будівництво будинку своїми руками (House made ofarbolit —DIY construction). Retrieved March 20, 2026, from https://stroyfibra.com.ua/budinok-z-arbolita-budivnictvo-budinku-svoimi-rukami/ (in Ukrainian). | uk |
| dc.relation.references | Shaik, S., & Setty, A. B. T. P. (2013). Analytical computation of admittance, decrement factor, time lag and surface factors for different exterior wall materials of the buildings in Dakshina Kannada district. In Proc. 22th Natl. 11th Int. ISHMT-ASME Heat Mass Transf. Conf. | en |
| dc.relation.references | Building Better with ISOTEX. Retrieved March 20, 2026, Retrieved March 20, 2026, from https://murotex.co.uk/about-us/. | en |
| dc.relation.references | Ukrainian National Standard. DSTU NB V.2.6-101:2010. (2010). Constructions of buildings and structures. Method for determination of thermal resistance of building envelopes. Kyiv, Institute of Technical Thermophysics of the National Academy of Sciences of Ukraine (in Ukrainian). | en |
| dc.relation.references | Ukrainian National Standard. DSTU 9191:2022. (2022). Thermal insulation of buildings. Method for selecting thermal insulation material for building insulation. (Official edition). Kyiv: Ministry of Economy of Ukraine (in Ukrainian). | en |
| dc.relation.references | Shea, A., Lawrence, M., & Walker, P. (2012). Hygrothermal performance of an experimental hemp-lime building. Construction and Building Materials, 36, 270–275. https://doi.org/10.1016/j.conbuildmat.2012.04.123. | en |
| dc.relation.references | Le, A. T., Maalouf, C., Mai, T. H., Wurtz, E., & Collet, F. (2010). Transient hygrothermal behaviour of a hemp concrete building envelope.Energy and buildings, 42(10), 1797-1806. https://doi.org/10.1016/j.enbuild.2010.05.016. | en |
| dc.relation.references | Evrard, A. (2008, May). Transient hygrothermal behaviour of lime-hemp materials (Doctoral thesis). Ecole Polytechnique de Louvain, Unité d’Architecture. | en |
| dc.relation.references | Walker, R., & Pavia, S. (2014). Moisture transfer and thermal properties of hemp-lime concretes. Construction and Building Materials, 64, 270-276. https://doi.org/10.1016/j.conbuildmat.2014.04.081. | en |
| dc.relation.references | Florentin, Y., Pearlmutter, D., Givoni, B., & Gal, E. (2017). A life-cycle energy and carbon analysis of hemp-lime bio-composite building materials.Energy and Buildings, 156, 293-305. https://doi.org/10.1016/j.enbuild.2017.09.097. | en |
| dc.relation.references | Porotherm –Wall solutions. Retrieved July 20, 2025 from https://porotherm.com.ua/pdf/Porotherm_P_W_RU.pdf. | en |
| dc.relation.references | Porotherm Technical datasheet Porotherm BIO Inc. 38 T. Retrieved July 20, 2025, from https://www.infobuild.it/wp-content/uploads/Porotherm-BIO-inc-38-25-19-T.pdf. | en |
| dc.relation.references | Neopor® –a Raw Material for Diverse Solutions. Retrieved July 19, 2025 from https://neopor.de/portal/load/fid1225927/Neopor_Thermal_insulation.pdf. | en |
| dc.relation.references | Eco2soft. Life cycle assessment of buildings. Retrieved June 28, 2025, from: https://www.baubook.at/eco2soft/?SW=27&LU=1823785713&qJ=1&LP=b4BKl&lng=2. | en |
| dc.relation.references | Rockwool SIUPERROCK. Retrieved July 20, 2025, from https://www.rockwool.com/ua/products-and-applications/products/ua-diy/SUPERROCK-UA/. | en |
| dc.relation.references | Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006). World map of the Köppen-Geiger climate classification updated. | en |
| dc.relation.references | Ukrainian National Standard. Energy efficiency of buildings. Building climatology: DSTU N B V.1.1-27:2010 (2010). (Official edition). Kyiv: Minregionbud of Ukraine. (in Ukrainian). | en |
| dc.relation.references | Вінницямісьтеплоенерго.Споживачам. URL: https://vmte.vn.ua/public/consumer/43 (дата звернення: 22.05.2026). | uk |
| dc.relation.references | Ukrainian National Building Code.Thermal insulation and energy efficiency of buildings: DBN V.2.6-31:2021 (2021). (Official edition). Kyiv: Ministry for Communities and Territories Development of Ukraine. (in Ukrainian). | en |
| dc.identifier.doi | https://doi.org/10.31649/2311-1429-2026-1-185-195 | |
| dc.identifier.orcid | https://orcid.org/0000-0002-5775-2014 | |
| dc.identifier.orcid | https://orcid.org/0000-0002-8231-9343 | |