Метод виділення контурів біомедичних зображень із використанням фільтрів та критерії їх ефективності
Вантажиться...
Дата
Назва журналу
Номер ISSN
Назва тому
DOI
Анотація
The paper is devoted to the division of the background and the object biomedical image. Consider an analysis on an example of a biomedical image processed using the developed software "Biomedical Imaging Analyzer". Consider the value of the PSNR criterion and the normalized NK correlation for the proposed software. From the results of the efficiency analysis, it should be noted that the value of the PSNR and the normalized NK correlation for the proposed software is higher than for the others, and the MSE mean square deviation and the normalized NMSE deviation are lower, indicating a more precise reproduction of a clear-cut image and a better quality and accurate image reproduction by the proposed method. Thus, the histogram of a biomedical image processed using the Biomedical Image Analyzer software has a clear rupture, unlike histograms of images processed by known methods, in which the spectrum of brightness remained uninterrupted. This indicates a clear separation of the background and object of the biomedical image.
Опис
Ключові слова
УДК
Тип документа
Мова
Бібліографічний опис
Оцінювання якості зображень томограм макулярної області сітківки ока [Текст] / С. В. Павлов, Й. Р. Салдан, С. М. Злепко [та ін.] // Інформаційні технології та комп'ютерна інженерія. – 2017. – № 3. – С. 14-22.
Схвалення
Рецензія
Доповнено
Цитується в
Список використаної літератури (4)
- Yosyp R. Saldan, Sergii V. Pavlov, Dina V. Vovkotrub, Yulia Y. Saldan, Valentina B. Vassilenko, Nadia I. Mazur, Daria V. Nikolaichuk, Waldemar Wójcik, Ryszard Romaniuk, Batyrbek Suleimenov, Ulan Bainazarov, "Efficiency of optical-electronic systems: methods application for the analysis of structural changes in the process of eye grounds diagnosis", Proc. SPIE 10445, Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2017, 104450S (7 August 2017); doi: 10.1117/12.2280977
- Romanyuk O.N. Microfacet distribution function for physically based bidirectional reflectance distribution functions / O. N. Romanyuk, S. V. Pavlov, R. Yu. Dovhaliuk, N. P. Babyuk, M. D. Obidnyk, P. Kisala, B. Suleimenov // Optical Fibers and Their Applications 2012. Lublin and Naleczow, Poland, Code 96466.
- Pavlov S.V. Using of fuzzy expert method for diagnostic glaucoma / S.V. Pavlov, A.O. Rozhman, N.P. Babyuk, I.D. Ivasyuk // “Вимірювальна та обчислювальна техніка в технологічних процесах”. Міжнародний науково-технічний журнал №2(43), 2013.– С.152-157.
- Pavlov S.V. Fuzzy expert opto-electronic system for the analysis of biomedical images (for example diagnosing glaucoma) / S.V. Pavlov, O.D. Azarov, I.R. Saldan, A.O. Rozhman, N.P. Babyuk // “Інформаційні технології та комп’ютерна інженерія”. Міжнародний науково-технічний журнал №1(26), 2013. –– С.8-14.