Показати скорочену інформацію

dc.contributor.authorBilynsky, Yo.en
dc.contributor.authorGromaszek, K.en
dc.contributor.authorStarovier, А.en
dc.contributor.authorDzis, V.en
dc.contributor.authorPaliy, V.en
dc.contributor.authorMoskovchuk, О.en
dc.contributor.authorAzhibekova, Z.en
dc.contributor.authorArypzhan, А.en
dc.contributor.authorБілинський, Й. Й.uk
dc.date.accessioned2026-01-08T10:41:11Z
dc.date.available2026-01-08T10:41:11Z
dc.date.issued2025
dc.identifier.citationBilynsky Yo., Gromaszek K., Starovier А., Dzis V., Paliy V., Moskovchuk О., Azhibekova Z., Arypzhan А. Enhancing diagnostic accuracy of fetal chromosomal abnormalities using automated ultrasound image processing of the nasal bone // Proc. SPIE. Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2025, Vol. 14009, Lublin, Poland, 30 December 2025. Lublin, 2025. DOI: https://doi.org/10.1117/12.3097617.en
dc.identifier.urihttps://ir.lib.vntu.edu.ua//handle/123456789/50388
dc.description.abstractThis paper presents an algorithm for the automatic processing of ultrasound images of the fetal head, aimed at detecting and measuring the nasal bone. Ultrasound examination during the first trimester (11–14 weeks) plays a critical role in assessing the risk of chromosomal abnormalities. However, visualizing the nasal bone can be challenging due to its small size and variability in image quality across ultrasound devices. The proposed algorithm combines Gaussian and median filtering for noise suppression and employs an improved Otsu segmentation method to enhance reliability. The system was validated using phantom-generated images as references, achieving a measurement accuracy within one pixel.en
dc.language.isoen_USen_US
dc.publisherSPIEen
dc.relation.ispartofProc. SPIE. Photonics Applications in Astronomy, Communications, Industry, and High Energy Physics Experiments 2025, Vol. 14009, Lublin, Poland, 30 December 2025.en
dc.subjectdiagnosticsen
dc.subjectultrasound imagingen
dc.subjectchromosomal anomalyen
dc.subjectnasal boneen
dc.subjectGaussian filtering and median filteringen
dc.subjectOtsu`s methoden
dc.subjectmeasurementen
dc.titleEnhancing diagnostic accuracy of fetal chromosomal abnormalities using automated ultrasound image processing of the nasal boneen
dc.typeArticle, Scopus-WoS
dc.identifier.doihttps://doi.org/10.1117/12.3097617
dc.identifier.orcidhttps://orcid.org/ORCID:0000-0002-9659-7221


Файли в цьому документі

Thumbnail

Даний документ включений в наступну(і) колекцію(ї)

Показати скорочену інформацію