Показати скорочену інформацію

dc.contributor.authorPolyvianchuk, A.en
dc.contributor.authorRomanenko, S.en
dc.contributor.authorSemenenko, R.en
dc.contributor.authorSemenenko, L.en
dc.contributor.authorYeskova, К.en
dc.contributor.authorПолив'янчук, А. П.uk
dc.contributor.authorСемененко, Р. А.uk
dc.date.accessioned2023-09-06T12:44:05Z
dc.date.available2023-09-06T12:44:05Z
dc.date.issued2019
dc.identifier.citationPolyvianchuk A., Romanenko S., Semenenko R., Semenenko L., Yeskova K. Complex assessment of the energy-saving measures effectiveness in the field of heat supply of educational institutions. Комунальне господарство міст. Серія «Технічні науки та архітектура». 2019. № 4 (157). С. 122–126.en
dc.identifier.issn2522-1817
dc.identifier.urihttp://ir.lib.vntu.edu.ua//handle/123456789/37839
dc.description.abstractРоботу присвячено вирішенню актуальної наукової проблеми - підвищенню інформативності методів оцінки ефективності енергозберігаючих заходів у сферах теплопостачання і теплоспоживання. Мета досліджень полягала у створенні та впровадженні методу багатокритеріальної оцінки ефективності енергозберігаючих заходів при теплозабезпеченні будівель. В якості критеріїв оцінки ефективності досліджуваних заходів за цим методом використовувались показники: 1) енергетичного ефекту – абсолютна та відносна величини збереженої теплової енергії; 2) екологічного ефекту – кількість збереженого палива, зменшення викидів парникових газів і забруднюючих речовин в атмосферу; 3) економічного ефект у – вартість економії теплової енергії та палива. Практична реалізація створеного методу була здійснена на базі 2-х натурних об'єктів: №1 - 3-поверхового фрагменту адміністративної будівлі ХНУМГ ім. О.М. Бекетова із загальною опалювальною площею 225 м2 та №2 – будівлі КЗ «Харківський палац дитячої та юнацької творчості» із загальною опалювальною площею понад 13700 м 2 . Для натурного об’єкту №1 оцінено ефективність використання технології «розумний дім» для управління тепловими режимами приміщень будівлі за допомогою автоматизованої системи HERZ Smart Comfort (HSC). Для натурного об’єкту №2 оцінено ефективність використання двох енергозберігаючих заходів: управління тепловими режимами приміщень будівлі системою HSC та використання альтернативного джерела теплопостачання – геліосистеми, яка складається з 180 сонячних колекторів. Результати досліджень показали такі властивості запропонованого методу оцінки ефективності енергозберігаючих заходів, як: висока інформативність результатів, що забезпечує можливість багатокритеріальної оптимізації параметрів систем теплопостачання та теплоспоживання об'єктів досліджень, здатність до вдосконалення за рахунок збільшення кількості досліджуваних показників ефективностіuk
dc.description.abstractThe work is devoted to solving an urgent scientific problem - increasing the informativeness of methods for assessing the effectiveness of energy saving measures in the areas of heat supply and heat consumption. The purpose of the research was to create and implement a method for multicriteria evaluation of the effectiveness of energysaving measures for the thermal energy of buildings. The following indicators are used as criteria for assessing the effectiveness of the studied measures in this method: 1) energy effect - the absolute and relative value of the saved thermal energy; 2) environmental effect - the amount of fuel saved, reducing emissions of greenhouse gases and pollutants into the atmosphere; 3) economic effect - the cost of saved thermal energy and fuel. The practical implementation of the created method was carried out on the basis of 2 full-scale objects: No. 1 - a 3-story fragment of the administrative building of Kharkov National University of Municipal Economy them. A.N. Beketova with a total heated area of 225 m2 and No. 2 - the building of the communal institution "Kharkov Palace of Children and Youth Creativity" with a total heated area of more than 13700 m2 . For full-scale object No. 1, the effectiveness of using «smart home» technology to control the thermal conditions of the building’s premises using the HERZ Smart Comfort automated system has been evaluated. For full-scale object No. 2 was evaluated the effectiveness of 2 energysaving measures: controlling the thermal conditions of the building’s premises with the HERZ Smart Comfort system and using an alternative heat source - heliosystem, which consists of 180 solar collectors. The research results showed such properties of the proposed method for evaluating the effectiveness of energy-saving measures, such as: high information content of the results, providing the possibility of multicriteria optimization of the parameters of heat supply systems and heat conuk
dc.language.isouk_UAuk_UA
dc.publisherХарківський національний університет міського господарства імені О. М. Бекетоваuk
dc.relation.ispartofКомунальне господарство міст. № 4 : 122–126.uk
dc.relation.ispartofseriesТехнічні науки та архітектураuk
dc.subjectheat supplyen
dc.subjectheated areaen
dc.subjectenergy saving measuresen
dc.subjectefficiencyen
dc.subjectcomplex assessmenten
dc.subjectnatural objecten
dc.subjecteducational institutionen
dc.subjectтеплопостачанняuk
dc.subjectопалювальна площаuk
dc.subjectенергозберігаючі заходиuk
dc.subjectефективністьuk
dc.subjectкомплексна оцінкаuk
dc.subjectнатурний об’єктuk
dc.subjectзаклад освітиuk
dc.titleComplex assessment of the energy-saving measures effectiveness in the field of heat supply of educational institutionsen
dc.typeArticle
dc.identifier.udc503.175; 621.43.06
dc.identifier.doihttps://doi.org/10.33042/2522-1809-2020-4-157-122-126


Файли в цьому документі

Thumbnail

Даний документ включений в наступну(і) колекцію(ї)

Показати скорочену інформацію